VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: AB108 Observer: G. Bower Project type: VLBA Obs filename: ab108crd.* Date/Day: 2003JAN24/024 Ants Used: NL FD LA PT KP OV BR MK =UT-Time===Comment===============================================MF#===%AD==AMD= Operators: J. Ogle and D. Pierce vclock and GPS delta okay. 0830 File began. 0934-0937 *PT Autostowed, commercial power glitch. COM 100 3 0940-0945 *PT pointing error, antenna was sitting off- ACU 100 5 source by about 10 arc-minutes for no apparent reason. Put antenna in standby and repointed, it returned to normal operation and went onsource. 1019-1024 *KP Focus motion analysis fault. FRM 100 5 1030 End. Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. wea = Weather entries: MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = TP/SP x Tcal/2