VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: BS181 Observer: Soderberg, A.M. Project type: VLBA Obs filename: bs181crd.* Date/Day: 2008FEB08/039 Ants Scheduled: SC HN NL FD LA PT KP OV BR MK =UT-Time===Comment===============================================MF#===%AD==AMD= Operator is Paul Padilla GPS delta, UT1-UTC, and VClock are all ok 0201 Begin at all sites except MK 0201-1203 *HN removed from observation - FRM is frozen in place 22168 100 602 0337 MK begins 0337-0354 %MK L107 errors. Also, +28V power supply seems to be 22199 100 17 down 0354-1203 *MK removed from observation. MK Site Techs contacte 22199 100 489 They will see if they have a spare power supply and get back to me later. 0401 MK Site Tech just contacted me. They do not have a spare +28V power supply, so I'll have to keep MK out for the remainder of the project. 0644 New operator Heidi Gerhardt 0935 %FD 35+ mph wind caution 1022 %PT 35+ mph wind caution 1104 SC ends 1203 End. Downtime Summary: Total downtime : 1108 min Percentage downtime of observing: 18.4% Average downtime per hour : 11.0 min Total scheduled observing time (# Antennas): 6020 min (10) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.