Welcome to program SCHED. Version: Release of 18 Sept. 2003 The manual is at http://www.aoc.nrao.edu/~cwalker/sched/sched/sched.html Unix users should set $SCHED to the base area where SCHED is installed. ** NEW ** Most run time messages will be in sched.runlog Some useful commands to give now if running interactively: SCHedule= : Specify input file. PLOT : Invokes uv, xy, rd, and uptime plotting. FREQLIST=lowF,highF : Make frequency list (MHz). Then exit. EXIT : Leave program. / : End of inputs - run program (or EXIT). TPINI: Reading tape initialization information from SCHED input file. SRREAD: Reading source catalog: Program_input SRREAD: Please convert source catalog from use of EPOCH to EQUINOX. RDSET: Reading setup file: GM059A.4cm STREAD: Reading station catalog: /sched-2003/catalogs/stations.dat STREAD: Will read locations file /sched-2003/catalogs/locations.dat SCHIN: Found 317 input scans. SCHIN: * Automatic tape allocation requested at: Br Fd Hn Kp La Mk Nl Pt Ov Sc Y Gb GETFREQ: Reading frequency file: /sched-2003/catalogs/freq.dat.2004sep27 SETFCAT: In setup: GM059A.4cm Station VLA27 Only 50.00 of 64.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. SETFCAT: In setup: GM059A.4cm Station ROB70 Only 47.49 of 64.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. SETFCAT: In setup: GM059A.4cm Station GOLD70 Only 47.49 of 64.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. SCHOPT: First output scan will be number 1 WRTMSG: Special message from routine AUTODOWN: * Stations using automatic tape allocation are being removed from scans when the source is below the antenna pointing limits. SCHOPT: There will be 317 output scans ( 1 - 317) from 51/14:07:00 to 52/01:55:53 SCHTIM: Caution: Only 4 readback tests (2 min gaps) at GOLD70 Please try for at least one readback each two hours. SCHTIM: VLBA_BR averages more than 10 tape stops per hour. SCHTIM: VLBA_FD averages more than 10 tape stops per hour. SCHTIM: VLBA_HN averages more than 10 tape stops per hour. SCHTIM: VLBA_KP averages more than 10 tape stops per hour. SCHTIM: VLBA_LA averages more than 10 tape stops per hour. SCHTIM: VLBA_MK averages more than 10 tape stops per hour. SCHTIM: VLBA_NL averages more than 10 tape stops per hour. SCHTIM: VLBA_PT averages more than 10 tape stops per hour. SCHTIM: VLBA_OV averages more than 10 tape stops per hour. SCHTIM: VLBA_SC averages more than 10 tape stops per hour. SCHTIM: VLA27 averages more than 10 tape stops per hour. SCHTIM: EB_VLBA averages more than 10 tape stops per hour. SCHTIM: MEDICINA averages more than 10 tape stops per hour. SCHTIM: GBT_VLBA averages more than 10 tape stops per hour. SCHTIM: ROB70 averages more than 10 tape stops per hour. SCHTIM: GOLD70 averages more than 10 tape stops per hour. Tape synchronization on the VLBA correlator is better when the tape does not stop often. Parameters MINPAUSE and PRESTART may be used to encourage continuous tape motion. FSFREQ: **** VLA BBC frequency ( 656.41) outside normal FSFREQ: range (600-650) at the VLA SUMOPE: Writing summary file gm059a.sum OMSOUT: Writing OMS file gm059a.oms VXWRT : Writing V E X file gm059a.skd FLAGS: Writing apriori flagging file gm059a.flag Processing VLBA_BR Processing VLBA_FD Processing VLBA_HN Processing VLBA_KP Processing VLBA_LA Processing VLBA_MK Processing VLBA_NL Processing VLBA_PT Processing VLBA_OV Processing VLBA_SC Processing VLA27 Processing EB_VLBA Processing MEDICINA Processing GBT_VLBA Processing ROB70 Processing GOLD70