Welcome to program SCHED. Version: 6.05 June 2006 The manual is at http://www.aoc.nrao.edu/~cwalker/sched/sched/sched.html Unix users should set $SCHED to the base area where SCHED is installed. Most run time messages will be in sched.runlog Some useful commands to give now if running interactively: SCHedule= : Specify input file. PLOT : Invokes uv, xy, rd, and uptime plotting. FREQLIST=lowF,highF : Make frequency list (MHz). Then exit. EXIT : Leave program. / : End of inputs - run program (or EXIT). SRREAD: Reading source catalog: Program_input RDSET: Reading setup file: atmos.set RDSET: Reading setup file: mrk1419.set STREAD: Reading station catalog: /home/arana/cwalker/sched/catalogs/stations.dat STREAD: Will read locations file /home/arana/cwalker/sched/catalogs/locations.dat SCHIN: Found 625 input scans. TPINI: Using default tape initialization information. SCHIN: * Automatic tape allocation requested at: Mk Br Ov Kp Fd Pt La Nl Hn Sc Gb Eb SRREAD: Reading source catalog: /home/arana/cwalker/sched/catalogs/sources.vlba GETFREQ: Reading frequency file: /home/arana/cwalker/sched/catalogs/freq.dat SHORTN: WARNING - Source names longer than 8 characters used. Mark III correlators and geodetic software will have problems. SETFCAT: In setup: mrk1419.set Station GBT_VLBA WRTMSG: Special message from routine SETFCAT: ----------- WARNING ----------- SCHED could not find a frequency catalog group that matched the setup file and station mentioned above. Below are the closest matches with at least some overlap in RF frequency. You can use FREQLIST (a main program input) to get the frequency catalog group and IF numbers that are available. Or you can look in freq.dat in the catalogs area. Since SCHED cannot confirm the validity of your setup, check and be very sure it is correct! In the table below, a match is indicated by a T. A mismatch is indicated by F. FreqCat Baseband FreqCat IF First Pol RF VLA FE RF RF Group Channel IF Name LO Chan 1 IF Freq Band gbt1cm_a3 1 2 T F T T T T T T gbt1cm_a3 2 1 T F T T T T T T gbt1cm_a3 3 2 T F T T T T T T gbt1cm_a3 4 2 T F T T T T T T gbt1cm_a3 5 1 T F T T T T T T gbt1cm_a3 6 2 T F T T T T T T gbt1cm_a3 7 2 T F T T T T T T gbt1cm_a3 8 1 T F T T T T T T --------------------------------------- TWOHDSET: Using 2 head (MkIV) or 2 tape (VLBA) wide band mode. SCHOPT: First output scan will be number 1 WRTMSG: Special message from routine AUTODOWN: * Stations using automatic tape allocation or disk recording systems are being removed from scans when the source is below the antenna pointing limits. This behavior can be overridden using DODOWN. WRTMSG: Special message from routine SETTPS: Tape is being kept running through short gaps between scans. Add TPSTART to the SUMITEM list to see details. MINPAUSE and PRESTART may be used to adjust. Remember MINPAUSE is multiplied by the speed up factor. SCHOPT: There will be 625 output scans ( 1 - 625) from 364/04:05:00 to 364/13:56:01 RESYNC: Scan 259 at VLBA_MK at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_BR at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_OV at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_KP at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_FD at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_PT at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_LA at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_NL at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_HN at 8.50 hr will be lost to correlator resync. RESYNC: Scan 259 at VLBA_SC at 8.50 hr will be lost to correlator resync. SUMOPE: Writing summary file bb231d.sum OMSOUT: Writing OMS file bb231d.oms FLAGS: Writing apriori flagging file bb231d.flag Processing VLBA_MK Processing VLBA_BR Processing VLBA_OV Processing VLBA_KP Processing VLBA_FD Processing VLBA_PT Processing VLBA_LA Processing VLBA_NL Processing VLBA_HN Processing VLBA_SC Processing GBT_VLBA Processing EB_VLBA