VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: BM193C Observer: Momjian, E. Project type: VLBA Obs filename: bm193ccrd.* Date/Day: 2003AUG30/242 Ants Used: SC HN NL FD LA PT KP OV BR MK Y =UT-Time===Comment===============================================MF#===%AD==AMD= 0230 Begin file - MK joins later VCLOCK check ok. SC at -0.155 UT1-UTC time check ok GPS delta < 10 us Operator: T. Perreault 0230 As the file started up, on several sites (HN OV, BR, KP, and LA) there were the following messages on LOGGER: doComent(): unrecognized type=0 text=tSuper: tNewd not running - will restart doComent(): unrecognized type=50 text=tNewd not running - will restart Then the program started immediately at all the aforementioned sites. 0230-0236 *PT program started but no monitor data was coming SW 100 6 back from the site. Did an RCMD reboot, station VME did not reboot all the way. Had to call in and do a reset of the station VME via the Sensaphone. Subsequent to the Sensaphone reboot, got the following SVR messages on LOGGER: doComent(): unrecognized type=0 text=tSuper: tNewd not running - will restart doComent(): unrecognized type=50 text=tNewd not running - will restart Also has to do a REOBS in order to get the tape to start writing. Did this before reaching source. 0416 *Y bad readback drive 2 tracks 16,17; all other sites ok 0452 MK as file started up at this site, got the same doComent messages as indicated above concerning tSuper and tNewd. The file started immediately following the messages. 0453 MK observing begins 0544 New operator is Jim Ogle. 0617 Readbacks okay. 0810 Readbacks okay. 1004 Readbacks okay. 1021-1023 *PT autostowed, commercial power glitch probably. COM 100 2 Repointed antenna. 1049-1052 *PT autostowed again. COM 100 3 1053 %Raining at FD. 1123 End at SC. 1157 Readbacks okay. 1158-1201 *HN tape not moving, stopped at end of first pass. SW 100 3 Manually moved tape forward then restarted scan, it started writing the reverse pass. 1213 End at HN. 1230 End. Downtime Summary: Total downtime : 14 min Percentage downtime of observing: 0.2% Average downtime per hour : 0.1 min Total scheduled observing time (# Antennas): 6600 min (11) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.