VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: BR121I Observer: Reid, M. Project type: VLBA Obs filename: br121icrd.* Date/Day: 2007APR22/112 Ants Scheduled: SC HN NL FD LA PT KP OV BR MK =UT-Time===Comment===============================================MF#===%AD==AMD= 0642 Begin file VCLOCK check ok. SC at -0.161 UT1-UTC check ok (-0.10) GPS delta < 10 us (NL: 8.8 us) Operator: T. Perreault 0642-0759 *SC not observing. EL motor current amps for 20238 100 77 both motors are over 40 amps and antenna is not moving in EL. Contacted oncall site tech, he will go out and take a look. Removed from observing so as not to use disk. 0759 SC repointed, on source. Problem appears to have been stuck motor brush. 1000-1006 *SC dropped out of pointing due to temporary loss COM 100 6 of commercial power. 1045-1050 *SC autostowed. Power glitch. Repointed. COM 100 5 1236 Site weather via webcams: SC: overcast HN: mostly clear NL, FD, PT: clear LA: webcam not updating 1314 Site weather update: KP: clear OV, BR: partly cloudy 1334 New Operator is Alan Kerr 1433 WEA: SC overcast; LA,OV,BR partly cloudy. 1444 End. Downtime Summary: Total downtime : 88 min Percentage downtime of observing: 1.8% Average downtime per hour : 1.1 min Total scheduled observing time (# Antennas): 4820 min (10) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.