VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: AG711B Observer: Richards,A. Project type: OTHER Obs filename: ag711bcrd.pt Date/Day: 2006APR01/091 Ants Scheduled: PT =UT-Time===Comment===============================================MF#===%AD==AMD= Operator is Brian Willard. GPS Delta, UT1-UTC, Vclock values nominal. Initial D-Rack temperature is 26.2C. Weather: broken clouds. 1654 Begin, PT antenna on source. 1754 D- Rack temperature is 26.1C. 1854 D-Rack temperature is 26.0C. 1954 D-Rack temp is 26.4C. 2054 D-Rack temp is 26.4C. 2154 D-Rack temperature is 26.1C. 2254 D-Rack temperature is 26.1C. 2354 D-Rack temp is 26.0C. 0000 Date is 2006APR02/092. 0054 D-Rack temp is 26.1C. 0154 D-Rack temp is 26.5C. 0230 New operator: T. Perreault 0254 D-rack temperature: 26.5 C 0330 End. Downtime Summary: Total downtime : 0 min Percentage downtime of observing: 0.0% Average downtime per hour : 0.0 min Total scheduled observing time (# Antennas): 636 min (1) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.