VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: AC817 Observer: C. Chandler Project type: OTHER Obs filename: ac817crd.pt Date/Day: 2006APR15/105 Ants Scheduled: PT =UT-Time===Comment===============================================MF#===%AD==AMD= Operator is Anthony Sowinski vclock and gps delta okay 1905 Begin 1905 D-rack temp is 26.1C 2005 D-rack temp is 26.2C 2107 D-rack temp is 26.3C 2207 D-rack temp is 26.4C 2307 D-rack temp is 25.7C 0000 Date is 2006APR16/106. 0004 D-rack temp is 26.0C 0104 D-rack temp is 26.0C 0145 Operator is Sonja Mendoza. 0205 D-Rack temp is 26.4C. 0304 D-Rack temp is 26.4C. 0304 End. Downtime Summary: Total downtime : 0 min Percentage downtime of observing: 0.0% Average downtime per hour : 0.0 min Total scheduled observing time (# Antennas): 479 min (1) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.