VERY LONG BASELINE ARRAY OBSERVING LOG -------------------------------------- Project: BB174F Observer: Bower, G. Project type: VLBA Obs filename: bb174fcrd.* Date/Day: 2004APR08/099 Ants Scheduled: SC HN NL FD LA PT KP OV BR MK =UT-Time===Comment===============================================MF#===%AD==AMD= 2002 Begin file. MK joins later. VCLOCK check ok. SC at -0.137 UT1-UTC check ok GPS delta < 10 us Operator: T. Perreault 2002-0202 %FD there is a continuous ACU flagging error 13746 that is false, data are ok. Suspect that this flagging error is caused by a bypass of the UPS system in the pedstal room. 2002-2030 *PT not observing. Extended maintenance visit. PM 100 28 2030-0202 *PT loss of internet and phone communication with COMM 100 332 the site. Phone line and T1 line are down. 2041 %LA wea: rain. 2045-2047 *KP autostowed. Power glitch. Site tech COM 100 2 repointed. 2126 PT Western NM Phone company called concerning loss of communications with PT site. Informed the tech that both voice and T1 lines are down. 2131 *LA bad readbacks on tracks 2 and 30, drive #2. Other sites okay. 2132 PT site tech called, informed them that Array Operations supervisor said not to upload any files to the site until stable communications are established. 2146 New operator is Jim Ogle. 2153-2154 *LA autostowed, commercial power glitch probably WEA 100 1 caused by the bad weather. 2249 %High wind gusts at OV. 2300 %OV reports overcast skies. Current sitecam image shows clear sky over the site though with overcast conditions out on the horizon. 2301 *LA bad readbacks on tracks 2 and 30, drive #2. Other sites okay. 2332 %Raining at FD. 0000 Date is 2004APR09/100. 0030 *LA bad readbacks on track 2. Other sites okay. 0050-0127 *FD tape drive #2 head positioning error, head not REC 100 37 moving at all. It just switched off of drive #1 so there is no option to switch to the other drive. 0103 &FD tech called out. 0127 FD tech has a new tape loaded on drive #1, switching over to that drive. 0202 End. Downtime Summary: Total downtime : 400 min Percentage downtime of observing: 11.1% Average downtime per hour : 6.7 min Total scheduled observing time (# Antennas): 3600 min (10) Notes: * = Entries where data was affected. % = Entries where data may have been affected. & = Entries where the site tech was called out. WEA = Weather entries. MF# = Maintenance form or major downtime category associated with a problem. %AD = The percentage of an antenna affected by a problem. AMD = Total antenna-minutes downtime for a problem. Tsys = System Temperature (TP/SP x Tcal/2) ACU = Antenna Control Unit FRM = Focus/Rotation Mount RFI = Radio Frequency Interference VME = Site control computer CB = Circuit Breaker vclock = Program that compares site clock time to a standard.